Product Description

SLP-PV170 V/U

SLP-PV170 V/U S

SPD type 2 – surge arrester for photovoltaic systems Replaceable varistor module, visual fault signaling Surge arrester is specially designed for installation in the direct current circuits of solar photovoltaic systems.Optional remote status signalling (S). Maximum continuous operating voltage for PV application

Technical data

SLP-PV170 V/U

Maximum continuous operating voltage (1/2-3) UCPV

170 V DC

Maximum continuous operating voltage – wiring “I” (1--2) UCPV

250 V DC

Nominal discharge current (8/20 μs) In

15 kA

Max. discharge current (8/20 μs) Imax

40 kA

Voltage protection level (1-2) Up

1,2 kV

Voltage protection level (1/2-3) Up

0,6 kV

Short-circuit withstand ISCWPV

63 A DC

Response time ta

25 ns

Degree of protection

IP 20

Range of operating temperatures

– 40 °C ... + 80 °C

Mounting on

DIN rail 35 mm

Cross-section of connected conductors

Solid min/max

Stranded min/max

 

ISO: 1/50 mm2 ; AWG: 17/1

ISO: 1/35 mm2 ; AWG: 17/2

Stripping length of the supply conductor

14 mm

Tightening torque

max. 4 Nm

Fault indication

red indication field

Remote indication – S design

potential-free change-over contact

Remote indication contacts

250 V / 0,5 A AC, 250 V / 0,1 A DC

Cross-section of remote indication conductors

max. 1,5 mm2

Meets the requirements

Ordering number:   SLP-PV170 V/U

                               SLP-PV170 V/U S

prEN 50539-11:2010T2

8595090536628

8595090536635

SLP-PV170 V/U

SLP-PV170 V/U S

SPD type 2 – surge arrester for photovoltaic systems Replaceable varistor module, visual fault signaling Surge arrester is specially designed for installation in the direct current circuits of solar photovoltaic systems.Optional remote status signalling (S). Maximum continuous operating voltage for PV application

Technical data

SLP-PV170 V/U

Maximum continuous operating voltage (1/2-3) UCPV

170 V DC

Maximum continuous operating voltage – wiring “I” (1--2) UCPV

250 V DC

Nominal discharge current (8/20 μs) In

15 kA

Max. discharge current (8/20 μs) Imax

40 kA

Voltage protection level (1-2) Up

1,2 kV

Voltage protection level (1/2-3) Up

0,6 kV

Short-circuit withstand ISCWPV

63 A DC

Response time ta

25 ns

Degree of protection

IP 20

Range of operating temperatures

– 40 °C ... + 80 °C

Mounting on

DIN rail 35 mm

Cross-section of connected conductors

Solid min/max

Stranded min/max

 

ISO: 1/50 mm2 ; AWG: 17/1

ISO: 1/35 mm2 ; AWG: 17/2

Stripping length of the supply conductor

14 mm

Tightening torque

max. 4 Nm

Fault indication

red indication field

Remote indication – S design

potential-free change-over contact

Remote indication contacts

250 V / 0,5 A AC, 250 V / 0,1 A DC

Cross-section of remote indication conductors

max. 1,5 mm2

Meets the requirements

Ordering number:   SLP-PV170 V/U

                               SLP-PV170 V/U S

prEN 50539-11:2010T2

8595090536628

8595090536635

Contact Us

Banarsi Complex, First Floor, Faizabad Road, Opp. Sbi Nishatganj, Lucknow, Uttar Pradesh, 226006, India
Phone :+917042637399